About the Society
HKSMS Activities
HKSMS activities (2012-2013)
HKSMS activities (2011-2012)
HKSMS activities (2010-2011)
HKSMS activities (2009-2010)
HKSMS activities (2008-2009)
Photo Gallery
Membership application
CALL FOR Abstract!! New!!!
Members' Corner
AGM minutes
Constitution
Presentation Materials
Local MS Resources, Distributions and Contacts
MS Group in CUHK
Hong Kong Jockey Club
Biomedical Mass Spectrometry Laboratory
MS Group at HKBU
Medical Proteomics Laboratory at CUHK
Plant metabolic engineering and systems biology Laboratory at CUHK
MS Group in PolyU
Useful Links
MS societies
MS suppliers
Useful MS software and web sites
Job Opportunities
Contact Us
Council members information
HKSMS correspondence address
 
 

Mass Spectrometry Group at HKBU

Contact Person: Dr. Zongwei Cai
   
Address: Rm. T1215, Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong SAR
   
Research Interests:
  1. Fundamentals and applications of
    • Mass spectrometry;
    • Nanospray ESI-MS;
  2. GC-, LC- and CE-MS for environmental, biological, pharmaceutical and Chinese medicinal analyses;
  3. Trace analysis of dioxins and other persistent organic pollutants.
MS Instrumentation:
  1. a. Applied Biosystem PE Sciex Q-Star Pulsar i (Quadrupole-Time of Flight) coupled with Agilent Cap-HPLC 1100
    • Equipped with ESI, APCI and Nano-spray sources
    • Capable of performing MS/MS and high-resolution MS analyses
  2. AutoSpec-Ultima double focusing magnetic-sector mass spectrometer couple with GC and auto-sampler
    • Equipped with EI, CI and FAB ionization sources
    • Capable of performing high-resolution ultra-trace analysis of dioxins, dioxin-like PCBs, PBDEs and PBDD/Fs
  3. Autoflex MALDI-TOF Mass Spectrometer (Bruker Daltonic)
    • Equipped with standard delay-ion extraction and reflectron mirror
    • Capable of performing post-source decay measurement
  4. Quadrupole GC/MS (Agilent 5975B series GC/MSD)
    • Equipped with EI, CI and FAB ionization sources
    • Capable of performing trace analysis of dioxins, dioxin-like PCBs, PBDEs and PBDD/Fs
  5. Esquire 4000 ion-trap LC/MSn (Bruker Daltonic)
    • Equipped with ESI and APCI ionization sources
  6. Acquity UPLC-triple quadrupole MS (Waters)
    • Equipped with ESI and APCI ionization sources
MS services:   No regular MS service  

Yes, please contact Dr. Zongwei Cai
Services include

  • LC-MS analysis
  • Dioxin analysis
  • High resolution ESI-MS analysis__________

For Research collaboration, please contact Dr. Zongwei Cai at (852)3411-7070 (or zwcai@hkbu.edu.hk)

 

 
 
 
 

Copyright©2013 Hong Kong Society of Mass Spectrometry. All rights reserved.